Early Alert: Outset Medical Updates Use Instructions for the Tablo Console and the TabloCart with Prefiltration Drawer
Get free alerts for this notice
Free account. We'll show updates and similar notices in your Dashboard.

The FDA has issued an Early Alert regarding a potentially high-risk device issue affecting the Tablo Console and the TabloCart with Prefiltration Drawer, both components of the Tablo Hemodialysis System manufactured by Outset Medical. The issue involves overheating at the connection between the power cord and the power inlet. Outset Medical has sent a letter to affected customers recommending updated use instructions. The affected devices include two specific power cords: the Power cord with clear ends (PN-0005746) for the Tablo Console and TabloCart with Prefiltration Drawer, and the Power cord with gray ends (PN-0008460) for the same devices. No specific retail stores, states, or countries are mentioned in the text; however, the devices are indicated for use in acute or chronic care facilities, and the recall is being managed in the United States. The reason for the alert is that Outset Medical received reports of overheating at the connection point between the power cord and the power inlet. This occurs when the connector is not held firmly in the inlet, leading to movement, increased electrical resistance, and heat generation. Both power cord versions have been involved in these reports. Signs of overheating include burning odors, smoke, warmth, melting, charring, discoloration, sparks, flames, audible electrical sounds, loose connectors, visible cord damage, tripped circuit breakers, unexpected power loss, or console alarms. A person touching the overheated connector could sustain first- or second-degree burns, and the Tablo Console may lose power, potentially delaying or interrupting treatment. As of November 10, 2026, no serious injuries or deaths have been reported. The Tablo Hemodialysis System is intended for patients with acute and/or chronic renal failure, with or without ultrafiltration, in acute or chronic care facilities. Customers in the U.S. with questions or issues should contact Outset Medical at 844-698-2256 or [email protected]. Adverse reactions or quality problems can also be reported to MedWatch, the FDA Safety Information and Adverse Event Reporting Program. The FDA is reviewing the information and will update its web page as significant new information becomes available. The content of the alert is current as of November 18, 2026.
Affected products
- Tablo Console
- TabloCart with Prefiltration Drawer