Early Alert: B. Braun Medical Inc. Updates Use Instructions for Caresite Micro Luer Access Device

FDA early alert · Source: FDA

Get free alerts for this notice

Free account. We'll show updates and similar notices in your Dashboard.

Caresite Micro Luer Access Device

The FDA has issued an Early Alert regarding a corrective action for the Caresite Micro Luer Access Device, specifically identifying component number S5404000. The product is a microvolume valve used to provide a sterile needle-free fluid pathway for the administration or aspiration of blood, IV therapy, or medications. The issue stems from an increasing number of complaints where the piston inside the female end of the device remained depressed after disconnecting a male luer connector, which can lead to backflow, visible leakage, and in less frequent cases, air ingress through the valve. The root cause has been confirmed as an absence of silicone lubricant at the piston location, making the piston more likely to stick in an open position. Potential clinical consequences include blood loss, interruption or delay of therapy, medication loss, air embolism, and microbial contamination risk. As of November 3, 2026, no serious injuries or deaths have been reported. The corrective action was initiated by B. Braun Medical Inc., which sent an Urgent Medical Device Correction letter to affected customers on November 13, 2026. The instructions apply to the device with component number S5404000, and the FDA has acknowledged that the action is being extended to the hospital and healthcare facility level. The text does not specify particular retail stores, states, or countries where the product was sold, but the contact information provided is for customers in the United States, indicating domestic distribution. The recommended actions include visually inspecting the device after disconnection of a male luer connector, and if leakage, backflow, or an open valve is observed, the device must be replaced using standard aseptic procedures. If the valve is bonded to an extension set, the entire set must be replaced; if it is a standalone valve, only the valve itself needs replacement. Distributors are instructed to forward the notice to their consignees, and healthcare facilities are advised to post the notification where the products are stored. The FDA is currently reviewing the issue and will update the public as new information becomes available. The complete list of affected products may include additional components beyond the single one listed, but the text only explicitly identifies the S5404000 component number.

Affected products

  • Caresite Micro Luer Access Device
    Models
    S5404000

Notice details

Contact
844-903-6417

View original