Convenience Kit Correction: Cardinal Health Updates Use Instructions for Presource Packs
Convenience Kit Correction: Cardinal Health Updates Use Instructions for Presource Packs Containing BD Alaris Pump Infusion Sets
This recall is ongoing.
Get free alerts for this recall
Free account. We'll show updates and similar recalls in your Dashboard.
The recalled products are Convenience Kit Correction: Cardinal Health Updates Use Instructions for Presource Packs Containing BD Alaris Pump Infusion Sets. This action is a correction to a previously issued Early Alert and does not involve removing the devices from where they are used or sold. The FDA has classified this as a Class I recall, meaning continued use without following the updated instructions could cause serious injury or death. The affected devices are specifically Presource Kits that contain BD Alaris Pump Infusion Sets. The underlying issue stems from a separate recall, Infusion Set Recall: BD and CareFusion 303, Inc. Remove BD Alaris Pump Infusion Sets, which identified that certain Alaris Pump sets with restrictive components perform worse than previously disclosed. This performance deviation is most common at low programmable rates under 1 mL/h and at or under 5 mL of bolus volume, potentially leading to under- or over-infusion, delayed occlusion alarms, and bolus dose inaccuracies. These issues may not be readily detected by users and pose the greatest risk to high-risk populations such as neonates, pediatrics, and critically ill patients. Cardinal Health sent a letter on September 23 to all affected customers, recommending they review the BD customer letter from August 19. The recommended actions include reviewing the Pump Infusion Set Performance Disclosures in Attachment B of BD's letter and adjusting clinical use. If the performance is not clinically appropriate, users should switch to an alternative pump, such as the BD Alaris Syringe Module. If no syringe pumps are available, the recalled sets may be used only with caution, enhanced clinical monitoring, and adherence to previously communicated warnings. Specific risk mitigation steps from the v12.3-v12.6 BD Alaris Infusion System User Manual include avoiding hanging the solution container below the pump module or higher than 21 inches above it, ensuring tubing is directly over pressure sensors, ensuring all clamps are open with no kinks, and not using Selectable pressure mode above 50 mmHg for rates less than 10 mL/h. When clearing an occlusion, fluid flow to the patient must be OFF, and tubing should be disconnected to relieve pressure. The correction notice does not specify individual states, countries, or specific store locations where the product is distributed, but the recall applies to the United States. Customers in the U.S. with adverse reactions, quality problems, or questions should contact their Cardinal Health sales representative. There is no list of model numbers, batch numbers, colors, or quantities provided for the Presource Kits in the text. The FDA has not received any reports of serious injuries or deaths associated with this issue as of August 19, 2026. The timeline shows the FDA issued an Early Alert on 10/20/2026 and classified the issue as a Class I Recall on 11/09/2026. Users are instructed to identify affected product in inventory and follow the updated use instructions.
Recall details
- Contact
- 1-888-INFO-FDA (1-888-463-6332)