Instrumentation Laboratories Removes HemosIL AcuStar HIT-IgG(PF4-H) recall

Platelet Factor 4 (PF4) Radioimmunoassay Recall: Instrumentation Laboratories Removes HemosIL AcuStar HIT-IgG(PF4-H)

U.S. Food and Drug Administration · Oct 30, 2026

Hazard: A performance issue

Check the official notice for affected lots and dates.

This recall is ongoing.

Get free alerts for this recall

Free account. We'll show updates and similar recalls in your Dashboard.

HemosIL AcuStar HIT-IgG(PF4-H)

The recall of the HemosIL AcuStar HIT-IgG(PF4-H) involves specific lots of this in vitro diagnostic medical device. The affected product is a qualitative, fully automated chemiluminescent immunoassay (CIA) used for the detection of IgG antibodies that react with Platelet Factor 4 (PF4) when complexed to heparin. The device aids in determining the risk for heparin-induced thrombocytopenia (HIT) when used with other laboratory and clinical findings. The recall was initiated by Instrumentation Laboratories (Werfen), and the FDA has identified this as a Class I recall, the most serious type, because continued use may cause serious injury or death. The performance issue causing the recall involves a negative bias in test results, potentially leading to false negative interpretations where samples are incorrectly reported below the assay cut-off of 1.00 U/mL. A false negative result may delay recognition of HIT, and continued heparin exposure could increase the risk of thrombotic complications. As of September 3, no serious injuries or deaths have been reported. The four affected lots are identified by specific lot numbers and part numbers, each with corresponding expiration dates. The devices included in the recall are listed below with their full product name, part number, and unique device identifier (UDI): - HemosIL AcuStar HIT-IgG(PF4-H), Part No. 0009800127, UDI 08426951126545, Lot No. B40005, B40006, B40078030. The affected lots include those with expiration dates of 2027--01-16, 2024-06-01, and 2023-06-01. The recall is classified as a Class I recall, indicating that the use of these devices may cause serious injury or death. The recall is ongoing, and the FDA has noted that this is a medical device recall, not a market withdrawal or safety alert. The affected product is a medical device, and the FDA has stated that this recall involves removing certain devices from where they are used or sold. It is important to note that the FDA has identified this recall as a Class I recall, and the affected devices are being removed from distribution due to a performance issue. The root cause investigation is ongoing, and no serious injuries or deaths have been reported. The recall is being conducted by Instrumentation Laboratories (Werfen), and they have issued letters to affected customers to recommend removal of the devices.

Affected products

  • HemosIL AcuStar HIT-IgG(PF4-H)
    Lots
    B40005, B38062, B40006, B38063
    Use by
    2027-01-16, 2026-11-01, 2027-01-16, 2026-11-01

Recall details

Contact
1-800-955-9525

View original